力士樂伺服驅(qū)動器維修電話:當(dāng)設(shè)備出現(xiàn)問題的時候大家都是比較凌亂的狀態(tài),不管是上網(wǎng)查詢還是借鑒說明書,一時間都不知道該怎么辦。為了避免這種情況,當(dāng)設(shè)備出現(xiàn)問題的時候可以聯(lián)系我們上海仰光電子18964852867.
力士樂伺服驅(qū)動器維修報價查詢:
F262故障含義:External Short at Status Outputs狀態(tài)輸出處的外部短路
Description:故障說明:
Status outputs are monitored for short circuits and thermal overload.
監(jiān)控狀態(tài)輸出是否存在短路和熱過載。
• If output current exceeds 350mA for about 1μs, then this is acknowledged as a short circuit and the pertinent channel is shut off.如果輸出電流超過350mA持續(xù)約1μs,則這被認(rèn)為是短路,相關(guān)通道被關(guān)閉。
The output remains off unti the error is cleared.
輸出保持關(guān)閉,直到錯誤被清除。
• With thermal overload, the error is set and the output(s) shut off. After the driver has cooled off, the outputs are switched back on and so on.
熱過載時,設(shè)置錯誤并關(guān)閉輸出驅(qū)動器已冷卻,輸出重新打開等。
The error, however, remains until it is cleared. Thermal overload can occur if several outputs are overloaded in excess of 80 mA.但是,錯誤將一直存在,直到清除為止。如果多個輸出過載超過80 mA,可能會發(fā)生熱過載。
Note: Light bulbs, for example, cannot be controlled as their inrush current causes a short-circuit.注:例如,燈泡無法控制其浪涌電流會引起短路。
Cause:原因:
1. Short circuited outputs (X2/6, X2/7, X2/8, X2/9, X2/10, X2/20, X2/21, X2/22)
短路輸出(X2/6、X2/7、X2/8、X2/9、X2/10、X2/20、X2/21、X2/22)
2. One or more outputs are overloaded.一個或多個輸出過載。
Remedy:解決措施:
1. Eliminate short circuit or limit switching current (< 350 mA)
消除短路或限制開關(guān)電流(<350 mA)
2. Drop current, depending on output, to < 80 mA.
根據(jù)輸出,降低電流至<80 mA。