力士樂(lè)英格瑪特伺服驅(qū)動(dòng)器維修:一般來(lái)說(shuō),如果博士力士樂(lè)伺服驅(qū)動(dòng)器一上電就報(bào)警,很有可能是驅(qū)動(dòng)器內(nèi)部主板壞了。如果在運(yùn)行中或通電一段時(shí)間后出現(xiàn)報(bào)警,則很可能是外部問(wèn)題引起的。
力士樂(lè)伺服驅(qū)動(dòng)器維修服務(wù);代碼查詢:
C208故障:Invalid SSI Parameter (-> S-0-0022)SSI參數(shù)無(wú)效(->S-0-0022)
Description:故障描述:
When the motors are first distributed, the parameter for absolute control emulation is purposely invalid to ensure that the "Set Absolute Measurement Emulator Command" will be executed after a motor is exchanged.首次分配電機(jī)時(shí),絕對(duì)控制仿真參數(shù)故意無(wú)效,以確保在更換電機(jī)后執(zhí)行“設(shè)置絕對(duì)測(cè)量模擬器命令”。
Cause:原因:
The SSI emulation was selected. The parameters required for emulation are invalid.
已選擇SSI仿真。仿真所需的參數(shù)無(wú)效。
Remedy:
Connect the control drive to a PC and activate DriveTop."Actual Position Output" menu with controller emulation type "Absolute將控制驅(qū)動(dòng)器連接到PC并激活DriveTop。控制器模擬類型為“絕對(duì)”的“實(shí)際位置輸出”菜單
Controller Emulation (SSI)":控制器仿真(SSI)“:
• Describe "Homing Position/Offset"
• Select "Absolute Control Directional Counter"
•描述“回零位置/偏移”
•選擇“絕對(duì)控制方向計(jì)數(shù)器”
力士樂(lè)伺服驅(qū)動(dòng)器維修服務(wù):
TDM系列故障:BS燈亮(無(wú)顯示屏系列),TS燈亮等
TDA系列故障(有液晶屏的)工作一會(huì)紅燈亮,液晶屏無(wú)顯示,報(bào)FEEDBACK,報(bào)MOTORVERTEMPERATURE等
DDS系列故障(數(shù)碼管顯示報(bào)警),無(wú)顯示,顯示60,顯示61等故障,
DKC系列故障:電機(jī)抖動(dòng),報(bào)F026,F229,F262,F860,C212等,
DKS系列故障:顯示61,無(wú)顯示,H1燈不亮,顯示25,顯示67等
RAC系列故障:報(bào)FEEDBACK,NO24V,PHASE,S-CIRCUIT等
HCS系列故障:報(bào)F2077,F8069,F8070等
TDV系列故障:H1B燈不亮,H2B燈不亮,H1A燈不亮等等
HVE系列故障:無(wú)顯示,顯示82,顯示25等
KDV2.3故障:指示燈不亮,紅燈亮
BOSCH DM系列故障:顯示30,顯示20,顯示60等
轉(zhuǎn)載請(qǐng)注明出處:上海仰光電子科技專業(yè)伺服驅(qū)動(dòng)器維修,伺服電機(jī)維修