南通力士樂DKS伺服驅動器C211故障維修可測試
故障代碼F2018 故障描述驅動器溫度報警 對策1降低環境溫度 2檢查柜內冷卻裝置 3清洗驅動器內部風扇 4驅動器內部溫度傳感器故障,更換HCS功率部分。
電源模塊維修,電梯電路板維修,驅動器維修,電路板復制,伺服放大器維修等服務,西門子,發那科,力士樂,施耐德,歐陸,安川,歐姆龍,東芝,臺安,松下ABB,AB,三菱,富士,LENZE,LG,大森,INDRAMANT,BARUFFALDI,哈斯數控加工。
有報警了,估計是硬件問題,自己修理不現實的,找我們吧。
HMS,HMD,HCS 如果直流母線的電壓低于驅動器參閱P00114,低壓極限值這是說明書給的答案,估計母線出問題了,需要維修找我們 daknkjifcmklx。
公司擅長維修產品:博士力士樂伺服驅動器、博士力士樂伺服電機、博士力士樂伺服電源 力士樂工控機等
二、經常維修的系列:HCS01,HCS02,HCS03,HMV,HMS,DKC01,DKC02,DKC03,DKC11,DKC05,HDS02.HDS04,TMD,DDS,HCS,HMS,HDD,HME,HMS,……
HCS03.1E-W0070
HMV01.1E-W0030
HMS01.1N-W0054
HCS02.1E-W0012-A-03-NNNN
HCS02.1E-W0028-A-03-NNNN
HCS02.1E-W0054-A-03-NNNN
HCS02.1E-W0070-A-03-NNNN
DKC02.3-040-7-FW
DKC11.3-040-7-FW
DKC01.3-040-7-FW
DKC01.1-040-7-FW
DKC05.3-040-7-FW
DKC01.1-040-3-FW(FWA-ECODRV-ASE-04VRS-MS)
DKC01.1-030-3-FW(FWR-ECODRV-ASE-04VRS-MS)
HDS02.2-W040N-HS23-0
HDS02.1-W040N-HS12-0
TDM1.4-100-300-W1-000
TDM1.2-050-300-W1-220
TDM1.2-100-300-W1-000
TDM1.3-100-300-W1-000
TDM3.2-20-300-W0
HAM1.2-15
DDS2.1-W100-D
DDS2.1-W025-D
DDS2.1-W050-D
TVD1.2-15-03
NFD03.1-480-016(INDRAMAT)
HDS04.2-W200N-HS84-01-FW
HDS04.1-W200N-HS12-01-FW
HDS03.2-W100N-HS12-01-FW
FWA-ECODR3-MGP-01VRS-MS
HCS03.1E-W100-A-05-NPBU
DKC01.3-200-7-FW
FWA-ECODR3-MGP-01VRS
HCS01.1E-W0008-A-03-B-ET-EC-NN-NN-NN-FW
MSK071E-0200-NN-M1-UG0-NNNN
RAC 3.1-100-460-L.0-HASE0V1.2
RAC 3.1-100-460-L.0-HASE0V1.4
DKC01.3-008-3-MGP-01VRS
HCL01.1C-02M4-A-007-NNNN
HMS01.1-W0070-A-07-NNNN
HVE03.2-W030
HMS01.1N-W0054-A-07-NNNN
CSB01.1N-SE-ENS-NNN-NN-S-NN-FW
CDB01.1-SE-ENS-ENS-NNN-NNN-NN-S-NN-FW
DKC02.3-100-7-FW
HDD02.2-W040N-HD32-01-FW
HMV01.1E-W0030-A-07-NNNN
HMS01.1N-W0070-A-07-NNNN
ECN 1313 512 62S12-71 I2C03
HMV01.1R-W0065-A007-NNNN
HMS01.1N-W0150-A-07-NNNN
PPC-R22.1N-N-NN-P2-NN-FW
HVE04.2-W075N
HMV01.1E-W0075-R-07-NNNN
DDC01.2-N100A-DL01-01-FW
HCS03.1E-W0100-A-05-NNBV
HVE02.2-W018N
HDS04.2-W200N-HS79-01-FW
四、庫存力士樂伺服電機/馬達型號:
SP 60-M1-4
SP 75-M2-16
MKD025B-144-KG1-UN
MSK040C-0600-NN-M1-UP1-NNNN
MSK050C-0300-NN-S1-UP0-NNNN
MDD041B-N-100-N2G-050PB0
MKD025B-144-KG0-KN
MKD090B-047-KP1-KS
MHD071B-001-NG0-UN
MKD071B-061-KG1-KN
MDD071A-N-030-N2S-095GB0
MDD090B-N-020-N21-110PA0
MAC063B-0GS-2-C/095-B-0/S001
MAC090C-0-GD-2-C/110-B-0
MAC092A-0-DD-2-C/095-A-1/S001
MAC112A-0-VD-1-B/130-A-1/-I01250
MKD041B-144-GG0-KN
MKD071B-061-GP0-KN
MKD090B-047-GPO-KN
MSK030B-0900-NN-M1-UP0-NNNN
MSK030B-0900-NN-S1-UG0-NNNN
MHD071B-061-PG0-UN
MAC071C-0-US-2-C/92S-B-1
MSK071E-0450-NN-S1-UP0-NNNN
MSK071E-0450-NN-M1-UP0-NNNN
2AD100C-B050B1-AS03-A2N1
MDD071B-N-040-N2T-095GB0
MKD041B-144-KP0-KN
MKD090B-047-KG1-KN
MAC112A-0-VD-1-B130-A-1-I01250
MDD071C-N-040-N2T-095GB2
MDD090C-N-030-N2M-110GB0
MDD112C-N-030-N2M-130GB0
MDD112D-N-030-N2M-130GB0
MAC071C-0-US-2-C 92S-B-1
MKD041B-144-KG1-KN
MKD090B-047-KG1
MKD071B-061-KG0-KN
MKD112D-027-GG0-BN
MHD115C-024-NG0-AA
MKD071B-061-KG0
MSK070D-0450-NN-M2-UG1-RNNN
MSK071E-0200-NN-M1-UG0-NNNN
五、力士樂維修中常碰到的故障現象:
TDM系列故障:BS燈亮(無顯示屏系列),TS燈亮等
TDA系列故障(有液晶屏的)工作一會紅燈亮,液晶屏無顯示,報FEEDBACK,報MOTORVERTEMPERATURE等
DDS系列故障(數碼管顯示報警),無顯示,顯示60,顯示61等故障,
DKC系列故障:電機抖動,報F026,F229,F262,F860,C212等,
DKS系列故障:顯示61,無顯示,H1燈不亮,顯示25,顯示67等
RAC系列故障:報FEEDBACK,NO24V,PHASE,S-CIRCUIT等
HCS系列故障:報F2077,F8069,F8070等
TDV系列故障:H1B燈不亮,H2B燈不亮,H1A燈不亮等等
HVE系列故障:無顯示,顯示82,顯示25等
KDV2.3故障:指示燈不亮,紅燈亮
BOSCH DM系列故障:顯示30,顯示20,顯示60等
REXROTH力士樂伺服驅動器維修系列:DSC3.1系列、DKR02.1/3.1/4.1系列、DKC系列、DDS系列、DKS系列;TVD系列、TDA系列、TDM系列;IndraDrive c 緊湊式驅動器 HCS01/2/3系列 ;IndraDrive M 模塊式逆變器HMS01 HMD01等
確認一下是不是伺服電機或者驅動器引起的故障如果確認是伺服電機引起的故障,不要去擅自拆開檢查內有高精密編碼器,以免造成二次故障專業力士樂伺服電機維修,了解更多可咨詢莞深機電的莫工。
轉載請注明出處:上海仰光電子科技專業伺服驅動器維修,伺服電機維修
本文鏈接:http://xdxxbc.com/fuwu/Services_Show12778.htm
伺服驅動器維修 伺服電機維修 觸摸屏維修 變頻器維修
電話:021-50157782
手機:13817011982 微信同號
郵箱:shygdzi@163.com
聯系人:張工
網址:http://xdxxbc.com
【 我們確保修好測試好給客戶!!!!】
下一篇:宿遷abb變頻器各種故障維修ACS800-17-0320-5報警2300維修