普陀區包米勒伺服驅動器維修:
1100Drive manager general error pulse enable
驅動器管理器一般錯誤脈沖使可能。
When a pulse block has no reason that can be recognized by the drive manager (AM) (recognizable are: digital input, error with response pulse block, command control word), there is a threat of an endless change of statuses in the AM:
當脈沖塊沒有驅動管理器(AM)可以識別的原因(可識別的有:數字輸入、響應脈沖塊錯誤、命令控制字)時,AM中存在狀態無休止變化的威脅:
Statuses 2->3->2 etc. are continuously processed because all switching conditions are met and the AM continues to attempt to activate the drive.
狀態2->3->2等將被連續處理,因為所有開關條件都已滿足,AM將繼續嘗試激活驅動器。
To prevent this, the change in status 3 will be disabled when a pulse block is recognized, a marker will be set and the error RC_ERR_DMGR_IF is entered for signaling.為了防止這種情況,當識別到脈沖塊時,狀態3的改變將被禁用,將設置標記,并輸入錯誤RC_ERR_D MGR_IF用于信令。
No change is possible in Status 3 as long as the marker is set.
只要設置了標記,狀態3就不可能更改。
Effect: The drive switches to Status 15 (Error). Other responses are no longer permitted so that the drive cannot automatically restart in the case above (pulse block without entering a error with pulse block) after Error #1100 has been reset.
影響:驅動器切換到狀態15(錯誤)。其他響應不再被允許,使得在錯誤#1100被重置之后,在上述情況下驅動器不能自動重新啟動(脈沖塊而沒有用脈沖塊輸入錯誤)。